Build.block &1: Quantity of stor.cond. exceeds quantity of initial sample

Message type: E = Error

Message class: RMXTSTABI - Messages for Stability Study in TMS

Message number: 063

Message text: Build.block &1: Quantity of stor.cond. exceeds quantity of initial sample



What causes this issue?

You have defined storage conditions and an initial sample when editing
the stability study building block.
The current quantity of storage conditions is viewed as the default
quantity per inspection. The total quantity required for the inspections
is multiplied by the number of planned inspections from the inspection
plan that was assigned. These quantities are then added together for all
storage conditions and are not allowed to exceed the quantity of the
initial sample.


System Response

The stability study building block cannot be assigned or copied and
assigned.


How to fix this error?

Correct the stability study building block so that the quantity of
storage conditions does not exceed the quantity of initial samples.


How to fix this error?

The system issues an error message and will not allow you to continue with this transaction until the error is resolved.