Technical table entries are missing; QCI cannot perform any conversion

Message type: E = Error

Message class: O3 - IS-Oil: HPM messages (goods movements, QCI, deliveries)

Message number: 343

Message text: Technical table entries are missing; QCI cannot perform any conversion



What causes this issue?

The system attempts to read the contents of Table OIB07. No entries were
found. The Quantity Conversion Interface (QCI) cannot perform any
conversion calculation.


System Response

The system stops processing.


How to fix this error?

Maintain Table OIB07 with the necessary entries (Transaction O589). SAP
delivers all required entries within the OILD46BHPM piece list
(technical table entry list) for release 4.6B and OILD46CHPM for
release 4.6C. For subsequent releases, check the IS OIL installation
manual.


Procedure for System Administrators

The system issues an error message and will not allow you to continue with this transaction until the error is resolved.