AGA8:Error code 14: Heating value is not within the valid range
Message type: E = Error
Message class: O3 - IS-Oil: HPM messages (goods movements, QCI, deliveries)
Message number: 281
Message text: AGA8:Error code 14: Heating value is not within the valid range
What causes this issue?
The test gross heating value HV is not within the valid range for the
AGA c-code.
System Response
The QCI (Quantity Conversion Interface) stops processing.
How to fix this error?
Enter a test gross heating value (HV) in the correct range.
The valid range is, according to the AGA c-code documentation:
477 < HV/ BTU per cubic foot < 1211 ,
or
17.7725 < HV / MJ per cubic meter < 45.12 .
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Procedure for System Administrators
Error message extract from SAP system. Copyright SAP SE.
Related Error Messages
O3280 AGA8:Error code 12: Flowing pressure (material pressure) is out of range
O3279 AGA8:Error code 13: Flowing temperature (mat. temperature)is out of range
O3282 AGA8:Error code 15: Natural gas relative density is not in valid range
O3283 AGA8:Error code 16: Mole fraction of components is not in valid range